IEC 60870-5
Source Code Library |
IEC
60870-5´Â International Electrotechnical
Commission(IEC) Technical Committee 57ÀÌ
°³¹ßÇÑ ÀϹÝÀûÀÎ ÇÁ·ÎÅäÄÝ °³³äÀÌ´Ù. À̰ÍÀº ÇÁ·ÎÅäÄÝ ±¸Á¶ÀÇOutlineÀ̸ç
¿ÀÁ÷ Companion Standard (Profile)¿Í¸¸ ½ÇÇàµÇ¾î 5°³ÀÇ
¸µÅ© ·¹À̾î Çü½Ä Áß Çϳª¿Í °°Àº ¿É¼ÇÀ» ÁöÁ¤ÇÑ´Ù. Triangle MicroWorks´Â
ÇöÀç ÁöÁ¤µÈ ¸ðµç Profile(101, 102, 103, 104)¿¡ ´ëÇÑ
Source Code Library¸¦ ½ÇÇàÇϰí ÀÖ´Ù. 101 ProfileÀº
IEEE Power Engineering SocietyÀÇ Substation
Committee°¡ RTU-IED Ä¿¹Â´ÏÄÉÀ̼ǿ¡ ÀûÇÕÇÑ ±ÇÀå Practice·Î
äÅÃÇÏ¿´´Ù. |
|
|
 |
 |
-
¾ö°ÝÇÑ
ÅëÇÕ Coding Standards ÇÏ¿¡ ANSI Standard C Source Code·Î
¾²¿©Áü
-
Target
¾ÖÇø®ÄÉÀÌ¼Ç ÀÎÅÍÆäÀ̽º·Î °£´ÜÇÏ°Ô ¼³Ä¡µÇ´Â ¡°Triangle¡±ÀÇ Source Code
Library
-
Event-Driven
or Non-Event-Driven ȯ°æ¿¡¼ »ç¿ëµÉ ¼ö ÀÖÀ½ (½Ç½Ã°£ ¿î¿µ ½Ã½ºÅÛ°úÀÇ
»ç¿ë ¿©ºÎ¿Í °ü°è ¾øÀ½)
-
°£´ÜÇÑ
Byte Order ¼³Á¤ : Most-Significant-First(Motorola),
Least-Signification-First(Intel)
-
1°³
¶Ç´Â 2°³ Octect Address Field¸¦ »ç¿ëÇÏ¿© Balanced¿Í Unbalanced
¸µÅ© ·¹ÀÌ¾î ¼³Á¤ Áö¿ø
-
Bitmapped
Time/Data Á¤º¸ Object¸¦ »ç¿ëÇÑ Clock Synchronization Command´Â
Àü¼Û°ú ÇÁ·Î¼¼½Ì Áö¿¬À» º¸»ó
-
ÇÁ·ÎÅäÄÝ
¸Þ½ÃÁö¸¦ ½Ã°¢ÀûÀ¸·Î ÇØµ¶ÇÒ ¼ö ÀÖ´Â Protocol Analyzer¸¦ Æ÷ÇÔÇÑ Æ÷°ýÀûÀÎ
ºôÆ®ÀÎ (Á¦°Å °¡´É)µÈ Áø´Ü. Áø´Ü°ú ºÐ¼®±â StringÀº Ÿ°Ù ½Ã½ºÅÛ µð½ºÇ÷¹ÀÌ Àåºñ,
½ÉÁö¾î ½Ã¸®¾ó Æ÷Æ®³ª RAM Buffer·Î ¹Ù·Î Àü¼ÛµÉ ¼ö ÀÖÀ½
-
Bad
Checksum, ºÎÁ¤È®ÇÑ Synchronization Byte, ¹«È¿ Frame ±æÀÌ¿Í
°°Àº Ä¿¹Â´ÏÄÉÀÌ¼Ç ÇÁ·ÎÅäÄÝ ¿¡·¯ Ç¥½Ã¸¦ µ¥ÀÌÅͺ£À̽º¿¡ Àü¼ÛÇÏ¿© »ç¿ëÀÚ°¡ Ãë±ÞÇÒ ¼ö ÀÖµµ·Ï
ÇÔ
|
|
 |
-
Ȱ¿ë
°¡´ÉÇÑ ¸ðµç »óÈ£ÀÛµ¿ Configuration ¼³Á¤À» Run-Time º¯¼ö³ª Function
Call¿¡ °¡»óÀûÀ¸·Î Á¢ÇÕ½ÃÅ´À¸·Î½á Á¤º¸Ã³¸®»óÈ£¿î¿ëÀÇ °¡´É¼ºÀ» ±Ø´ëÈ ÇÔ
-
¹«ÇÑÇÑ Ä¿¹Â´ÏÄÉÀÌ¼Ç Æ÷Æ®¸¦ ÅëÇØ ¹«ÇÑÇÑ È£½ºÆ® ÀåÄ¡·Î µ¥ÀÌÅ͸¦ °ø±Þ
-
Multiple
Application Layer ASDU Address(Sector)¸¦ Áö¿ø. ÀÌ °¡»ó
ÀåÄ¡ÀÇ ´É·ÂÀº ƯÀ¯ÀÇ µ¥ÀÌÅͺ£À̽º ProfileÀ̳ª µ¥ÀÌÅͺ£À̽º Profile¿¡°Ô È£½ºÆ®
½ºÅ×À̼ÇÀ¸·ÎÀÇ °øÅë ¿ä¼Ò¸¦ Á¦°øÇÑ´Ù.
-
Database
Manager´Â ·£´ýÇÏ°Ô Á¶Á÷µÈ Target Application Data Points
(Binaries, Controls, Integers, Flots µî)¸¦ IEC60870-5-101
ASDU Type Information Object·Î Map ÇÔ
-
½Ã¹Ä·¹ÀÌÆ®
µÈ Database Interface ½ÇÇàÀÇ ¿¹°¡ ÀÏ·¯½ºÆ®·¹ÀÌ¼Ç ¹× ÃÖÁ¾ Database
Interface °³¹ß¿¡ »ç¿ëµÉ Template ¿ëÀ¸·Î Á¦°øµÈ´Ù.
-
CP24Time2a(24-bit
Time Tag), ÀûÀýÇÑ Clock Synchronization CommandsÀÇ »ç¿ë,
½Ã°£º° Rollover ¹ß»ý½Ã ÀÚ¹ßÀû Clock Synchronization ÀÀ´äÀ» ÇÏ´Â
ASDU ŸÀÔÀ» ¿Ïº®ÇÏ°Ô Áö¿ø
-
CP56Time2a(56-bit
Time Tag)À» Áö´Ñ ASDU ŸÀÔ¿¡ ÀûÇÕÇÑ Áö¿øÀ» Æ÷ÇÔ. À̰ÍÀº ½ÂÀÎµÈ ¡°Addendum
to IEC 60870-5-101 Concerning the Extension of Time
Tags¡±°¡ ÁöÁ¤ÇÑ 30-40°³ÀÇ ASDU ŸÀÔÀ» Æ÷ÇÔÇÔ.
-
ASDU
ŸÀÔÀº Class 1À̳ª Class 2·Î °³º°ÀûÀ¸·Î ÇÒ´çµÊ
-
Target
Application DataÀÇ ¼³Á¤ °¡´ÉÇÑ ½ºÄµÀÌ ÀÚ¹ßÀû ÀÀ´ä µ¥ÀÌÅ͸¦ ÀÚµ¿ÀûÀ¸·Î ¹ß»ý½ÃÅ´
|
|
 |
- ¹«Á¦ÇÑÀÇ
Communication Port »ó¿¡¼ ¹«Á¦ÇÑÀÇ Remote Device¸¦ ¼³Á¤ÇÒ ¼ö
ÀÖÀ¸¸ç, Runtime ½Ã »õ·Î¿î Device¸¦ Ãß°¡ÇÒ ¼ö ÀÖÀ½
- »óÀÌÇÑ Field
»çÀÌÁî(ASDU Address, Àü¼Û ¿øÀÎ, Information Address)¸¦ Áö´Ñ
µ¿ÀÏÇÑ Ä¿¹Â´ÏÄÉÀÌ¼Ç Æ÷Æ®»óÀÇ Àåºñ³ª, »óÀÌÇÑ ¸µÅ© Address »çÀÌÁ Áö´Ñ ºÐ¸®µÈ
Ä¿¹Â´ÏÄÉÀÌ¼Ç Æ÷Æ®»óÀÇ Àåºñ¿Í Åë½ÅÇÔ
- ASCII¿¡
±â¹ÝÇÑ SACDA Man Machine Interface(MMI)´Â Commands¸¦
ÃʱâÈ ÇÏ°í ¿ä±¸ »çÇ×À» Àаí, ÀÛµ¿À» ¸ØÃâ °æ¿ì¿¡ »ç¿ëµÉ ¼ö ÀÖÀ½
- Database
Manager´Â ¼ö½ÅµÈ IEC 60870-5 Data Object¸¦ Target Application
Data Points(Binaries, Controls, Integers, Floats
µî)¿¡ MapÇÔ
|
 |
|
|
|
| |
|
|